Hi All.... is it possible to run four 100w spotties of the one relay..bb
want33s
Joined: 27 Dec 2006
Location: Sunshine Coast Qld
Posted:
Thu Oct 16, 2008 2:23 pm
Yeah sure IF you can find a large enough relay...
4 X 100w = 400w
400w / 12V = 33.3333A
You will need at least 40A relay and wiring but I would go 50A to be safe.
Fit a fuse (40A) between battery and relay and another between relay and lights.
Jas.
_________________ My old cut down f'glass top is for sale if anyone wants to make an offer. Pics in my build thread in members.
drivesafe
Joined: 11 Dec 2004
Location: Gold Coast
Posted:
Thu Oct 16, 2008 4:08 pm
Hi bob, the largest standard blade fuse is 35 amps and a 40 amp fuse would not be big enough, so the cost of the over sized fuse and the large relay just does not make it worth the trouble of trying to fit just one relay.
It would be cheaper and safer to fit two separate 30 or 40 amp headlight relays and each relay protected by a 30 amp fuses.
_________________ 2007 TDV8 Range Rover Lux
2005 SE V6 Discovery
Bingara Bob
Joined: 17 Dec 2007
Location: Bingara NSW
Posted:
Thu Oct 16, 2008 6:07 pm
Thanks a heap fella`s......will go with drivesafe`s idea